ADRIAN-RAD ELECTRO V66/15 & V66/20 Electric Infrared Heaters
ADRIAN-RAD ELECTRO ATEX is a range of electric infrared heaters designed for applications where safe heating is required in potentially explosive atmospheres.
Kód produktu: RAD ELECTRO V
I am interested in the productThe EHSAFE15VR and EHSAFE20VR models are designed and manufactured using proven technical solutions and components in compliance with the relevant regulations and requirements for safe operation.
The units are intended for installation in potentially explosive atmospheres in Zone 2 and Zone 22, in accordance with Directives 2014/34/EUand 1999/92/EC.
Main advantages
ATEX design
Suitable for use in potentially explosive atmospheres in Zone 2 (gases and vapours) and Zone 22 (combustible dust).
Two power variants
1.5 kW and 2.0 kW.
IP66 protection
Both models have an IP66 protection rating.
Clearly defined safety limits for ATEX environments
When designing and installing the system, the ignition temperature of gases, vapours and dust, as well as the maximum ambient temperature, must be taken into account.
Two power variants
| Parameter | EHSAFE15VR / ATEX 1500 | EHSAFE20VR / ATEX 2000 |
|---|---|---|
| Power output | 1,500 W | 2,000 W |
| Voltage | 208–240 V | 208–240 V |
| Frequency | 50/60 Hz | 50/60 Hz |
| Material / colour | Mica iron | Mica iron |
| Indicative heated area | ~15 m² | ~20 m² |
| Protection rating |
ADRIAN-RAD ELECTRO ATEX 1500
Model: EHSAFE15VR
Power output: 1.5 kW
The EHSAFE15VR is the lower-output version of the ADRIAN-RAD ELECTRO ATEX range. It is designed for applications in potentially explosive atmospheres in Zone 2 and Zone 22 and provides an output of 1,500 W.
ADRIAN-RAD ELECTRO ATEX 2000
Model: EHSAFE20VR
Power output: 2.0 kW
The EHSAFE20VR is the higher-output version of the ADRIAN-RAD ELECTRO ATEX range, with a heat output of 2,000 W.
Important safety information
For equipment intended for use in potentially explosive atmospheres, particular attention must be paid to the conditions of the specific application. The heater must not be installed in areas containing vapours or gases with an ignition temperature below 300 °C.
Different limits apply in dusty environments depending on the model:
- EHSAFE20VR / ATEX 2000: minimum dust ignition temperature 290 °C
- EHSAFE15VR / ATEX 1500: minimum dust ignition temperature 230 °C
Neither model may be used in environments with an ambient temperature above 25 °C, whether gases or dust are present. When designing and installing the system, the classification shown on the rating plate of the specific heater must always be checked.
Installation clearances
| Parameter | EHSAFE15VR | EHSAFE20VR |
|---|---|---|
| Height above floor level | 2.5–3.0 m | 2.5–3.0 m |
| Minimum distance from the ceiling | 320 mm | 320 mm |
| Minimum distance from the wall | 1,000 mm | 1,000 mm |
| Distance from combustible materials – front | 2.0 m | 2.0 m |
| Distance from combustible materials – sides | 1,000 mm | 1,000 mm |
Why choose ADRIAN-RAD ELECTRO ATEX
This solution is designed for applications where a standard electric infrared heater is not suitable due to the requirements of potentially explosive atmospheres.
The key advantages include a combination of:
- ATEX design,
- two power variants,
- IP66 protection,
- compact dimensions,
- clearly defined installation and safety requirements.